- Site: Transport Competent Authority
- IR number: 21-004
- Date: May 2021
- LC numbers: N/A
Executive summary
ONR regulates the civil transport of radioactive material by road, rail and inland waterway in Great Britain (GB). The ONR Transport Competent Authority (TCA) is responsible for delivering non-nuclear transport inspection and enforcement activities. This particular inspection forms part of that delivery function with reference to Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2009 (CDG) and the Ionising Radiations Regulations 2017 (IRR17). CDG refers to the European Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) and ONR used ADR 2019 during this inspection (www.unece.org).
Purpose of Intervention
The purpose of the inspection was to review Royal Marsden Hospital Foundation Trust’s (RM’s) arrangements associated with the road transport of radioactive material. ONR carried out this inspection virtually using MS Teams on 10th May 2021.
Interventions Carried Out by ONR
The chosen inspection sample included:
- notification, registration or consent – IRR17 Regulation 5, 6 or 7;
- a suitable and sufficient radiation risk assessment (RRA) – IRR17 Regulation 8;
- suitable and sufficient contingency planning and/or emergency arrangements – IRR17 Regulation 13 and CDG Regulation 24 & Schedule 2;
- adequate information, instruction and training – IRR17 Regulation 15 and ADR 1.3.1;
- adequate safety advice – ADR 1.8.3 and IRR17 regulation 14;
- adequate local rules – IRR17 regulation 18
- adequate transport documentation – ADR 5.1.5.2
- adequate security arrangements – ADR 1.10;
- a suitable and sufficient management system – ADR 1.7.3
Key Findings, Inspector's Opinions and Reasons for Judgements Made
The inspector sampled the arrangements deployed by RM for the safe transport of radioactive materials, including the associated arrangements for protecting workers against the effects of ionising radiations and reducing risks as low as reasonably practicable (ALARP).
The inspector compared relevant statutory requirements with both prescribed arrangements and actual practice. The inspector identified a number of examples of the duty holder meeting relevant good practice in reducing risk to levels that are ALARP, including having a Radiation Risk Assessment (RRA), associated Local Rules, Contingency Plans, an appointed RPA and DGSA. The inspector identified five non-compliances and discussed these during the inspection, which included periodic review and revision of RRAs; provision of reports every 3 years regarding emergency testing to the GB Competent Authority (CA); ensuring that certificates of conformance are present for packaging and considering operating instructions for use of packaging; and security responsibilities and training.
Conclusion of Intervention
RM demonstrated that for certain aspects of its operations it met the requirements of CDG, ADR and IRR17.
Based on the inspection sample, the inspector identified five non-compliances with relevant legislation. The inspector discussed these during the inspection and RM gave a commitment to address them.
The inspector gave RM until 21st June 2021 to provide ONR either with evidence that the findings have been resolved, or an appropriate resolution plan with timescales for completion.
For this intervention, the inspector gave an inspection rating of AMBER, due to there being some deficiencies identified within its arrangements for compliance with legal requirements. These relate to the five areas of non-compliance identified during the inspection.
ONR will monitor the identified non-compliances through its issues management arrangements.