Skip to content

Chapelcross LC11, LC17; Site meetings

  • Site: Chapelcross
  • IR number: 21-163
  • Date: February 2022
  • LC numbers: 11, 17

Executive summary

Purpose of Intervention

These Licence Compliance Inspections were carried out as part of a series of planned inspections for the Chapelcross (CHX) decommissioning site during 2021/22.

Interventions Carried Out by ONR

 I carried out Licence Compliance inspections on CHX’s Licence Condition (LC) 11 and 17 arrangements and their implementation. I also held an update meeting with the CHX Safety Representatives.

Explanation of Judgement if Safety System Not Judged to be Adequate

N/A

Key Findings, Inspector's Opinions and Reasons for Judgements Made

From the documentation examined and the areas inspected, I found that CHX’s implementation of its LC11 (Emergency arrangements), and LC17 (Management Systems) arrangements were adequate.

Conclusion of Intervention

I judged that CHX’s implementation of its LC11 and LC17 arrangements as adequate in the areas inspected and I did not identify any significant regulatory concerns.