Skip to content

Springfields Works - Inspection ID: 53574

Executive summary

  • Date(s) of inspection: December 2024

Aim of inspection

Confirmation that corrective actions from Springfields Fuels Ltd investigations into events on site are being adequately progressed, monitored, closed and that appropriate learning from the events is secured to prevent re-occurrence.

Subject(s) of inspection

  • LC7 - Incidents on the site - Rating: Green
  • LC17 - Management systems - Rating: Green

Key findings, inspector's opinions and reasons for judgement made

The inspection at Springfields Fuels Limited focused on corrective actions identified from investigations undertaken on incidents reported to ONR under licence condition (LC)7 incidents on the site.

The inspection sampled corrective action management and close out information. It provided confidence that corrective actions from investigation of incidents are well managed proportionately to the incident safety significance. I was content that the actions completed following investigations would ensure risks to workers would be minimised and help prevent a recurrence.

Opportunities for improvement of the corrective action process were identified from the inspection process but I consider these as refinement of the process rather than systemic shortfalls.

Corrective actions for security related incidents are managed by a slightly different process due to the security limitations of the dutyholders corrective action database. These differences have not been documented within the dutyholders business management system. A level 4 regulatory issue has therefore been raised to for the dutyholder to formally record the full process for the management and governance of security related corrective actions.

Conclusion

The inspection focused on corrective action management. Based on the sampling undertaken, I rate the LC7 and LC17 intervention as GREEN – ‘No Formal Action’. This rating is in line with the established ONR guidance.

  • “Relevant good practice generally met, or minor shortfalls identified, when compared with appropriate benchmarks.”
  • “No significant shortfalls identified in the delivery of safety, safeguards or security functions.”

None of the findings in the inspection presented an immediate or direct risk to nuclear safety.