On this page you will find detail of the Summary and supporting Technical Reports published in relation to the UK ABWR. These reports are internal ONR reports that are published on this website in the interests of openness and transparency.
Step 4
Step 4 Assessment Reports
- Step 4 Assessment of Civil Engineering for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-013)
- Step 4 Assessment of Probabilistic Safety Analysis for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-014)
- Step 4 Assessment of Severe Accidents for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-015)
- Step 4 Assessment of Fault Studies for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-016)
- Step 4 Assessment of Control and Instrumentation for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-017)
- Step 4 Assessment of Electrical Engineering for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-018)
- Step 4 Assessment of Fuel & Core Design for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-019)
- Step 4 Assessment of Chemistry for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-020)
- Step 4 Assessment of Radiological Protection for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-021)
- Step 4 Assessment of Mechanical Engineering for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-022)
- Step 4 Assessment of Management for Safety and Quality Assurance for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-024)
- Step 4 Assessment of Management of Radioactive Wastes for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-025)
- Step 4 Assessment of Conceptual Security Arrangements for the UK Advanced Boiling Water Reactor(ONR-NR-AR-17-026)
- Step 4 Assessment of External Hazards for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-027)
- Step 4 Assessment of Conventional Health and Safety for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-028)
- Step 4 Assessment of Spent Fuel Interim Storage for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-030)
- Step 4 Assessment of Internal Hazards for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-033)
- Step 4 Assessment of Decommissioning for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-034)
- Step 4 Assessment of Fire Safety for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-036)
- Step 4 Assessment of Structural Integrity for the UK Advanced Boiling Water Reactor (ONR-NR-AR-17-037)
Step 3
Step 2
Step 2 Assessment summary reports - Hitachi-GE Nuclear Energy's UK Advanced Boiling Water Reactor (UK ABWR)
Step 2 Technical reports - Hitachi-GE Nuclear Energy's UK Advanced Boiling Water Reactor (UK ABWR)
- Control and instrumentation
- Civil engineering and external hazards
- Electrical engineering
- Fault studies
- Fire safety
- Fuel and core
- Human factors
- Internal hazards
- Mechanical engineering
- MSQA
- PSA
- Radiological protection
- Radioactive waste and decommissioning
- Reactor chemistry
- Security
- Structural integrity